Emergency Eyewash Station Requirements
Corrosive chemical splashes can injure eyes within seconds, and OSHA requires quick-flushing facilities wherever workers may be exposed to injurious corrosives. See what makes an eyewash station suitable, how close it should sit to the hazard, and how clear signs help crews reach it.
A station nobody can find in a hurry is not much help to someone who can't see. A green and white eye wash station sign above each unit marks the spot from across the room, so a coworker can guide an injured worker straight to the water.
What OSHA requires
The general industry rule is short. Under 29 CFR 1910.151(c), where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. Construction sites have the same language in 29 CFR 1926.50(g).
Other OSHA standards add their own flushing rules for specific hazards. Forklift battery charging areas are one example, and the battery charging area safety guide covers the acid, hydrogen and eyewash basics for those rooms.
The OSHA rule does not define "suitable," list a travel distance or set a water temperature. That is where the consensus standard comes in.
How ANSI Z358.1 fills the gaps
OSHA has said in a letter of interpretation that guidance on suitability may be found in consensus standards such as ANSI Z358.1, the American National Standard for Emergency Eyewash and Shower Equipment. OSHA does not enforce consensus standards, but the same letter notes that an eyewash that complies with the ANSI standard will usually meet the intent of the OSHA rule.
State plans lean on it too. Minnesota OSHA's eyewash and shower directive uses ANSI Z358.1-2014 to judge units and lists these points:
Travel time: Units should be within 10 seconds of the hazard and on the same level. ANSI's appendix puts that at about 55 feet at a normal walking pace. For strong acids or bases, the eyewash should be immediately adjacent to the hazard.
Flow: Eyewashes deliver at least 0.4 gallons per minute for 15 minutes to both eyes at once. Showers deliver at least 20 gallons per minute.
Water temperature: Flushing fluid should be tepid, roughly 60 to 100 degrees Fahrenheit, because water outside that range discourages people from staying under it.
Access and visibility: The path must be unobstructed, and the location should be well lit, highly visible and marked with a highly visible sign.
Testing: Plumbed eyewashes and showers should be flushed weekly to confirm they work.
The safety data sheet for each chemical is the other key reference. Section 4 lists first-aid measures, including how long to flush, and current SDSs are part of the HazCom update every employer is working through.
Where stations and signs belong
Walk the site with the SDS binder and mark every place a corrosive is poured, mixed, charged or stored. These are the spots most often missed.
Battery charging and maintenance: Electrolyte splashes happen during watering and handling. Mark the station at the charger row, not around the corner.
Chemical dispensing and mixing: Drum pumps, caustic cleaners and acid transfers need a unit within the 10-second reach. A DANGER Sulfuric Acid label on the tank or storage area names the hazard so workers know why the eyewash is there.
Combination units: Where both eyes and body may be splashed, a drench shower and eyewash often share one station. An Emergency Shower and Eyewash label identifies both on one sign.
Labs, wastewater and water treatment: Pool chemicals, chlorine compounds and pH adjusters are common corrosives in these sites.
Construction and remote sites: Self-contained portable units count when plumbing isn't available. Sign them as clearly as a permanent unit, and check fluid expiration dates.
Pair the station sign with an entry reminder. A NOTICE Eye Protection Required label, an OSHA-style design, at the door of a chemical area tells people to wear goggles before the eyewash is ever needed.
Make the sign easy to see
Mount the sign above the unit, high enough to clear carts, drums and stacked pallets. Keep the area under and in front of it clear of stored material. Where the unit sits in an alcove or behind equipment, add a second sign on the aisle side. VLG's emergency signage line covers eyewash, shower, exit and first aid messages for the full route.
Replace any sign that is faded, splashed with chemicals or peeling at the corners. Clean and dry the surface before applying a new label so the adhesive bonds to the wall, not to residue.
Before you order
Count every eyewash, drench shower and combination unit, plus each portable station, before ordering. Large plants usually need more signs than units, because stations around corners need aisle-side markers too.
VLG labels are Printed in the USA on premium low-shrinkage calendered vinyl with an industrial strength adhesive, made to hold on block walls, steel panels and painted surfaces in wet areas. The Sulfuric Acid label uses an ANSI Z535-style layout. Facilities with many stations can order in bulk, and custom wording, such as a station number or a site-specific chemical name, can be printed to order.
This post is general safety information, not legal advice. Check the full text of 29 CFR 1910.151, 1926.50, the ANSI/ISEA Z358.1 standard, your chemicals' safety data sheets and any state plan rules that apply to your site.